Protected single-pole DC contactors with mounted brackets: T106, T206, T154 and T204; 12 / 24 / 36 V DC coils, DC5 utilisation category, 2 million operations.

TECNO Series DC Contactors

TECNO Series DC Contactors

Compact and robust, TECNO series DC contactors are designed for direct-current material handling machinery and industrial electric vehicles such as lift trucks, industrial cleaning machines, ships and boats, and road and rail transport vehicles. They are also used in renewable-energy converters, electric motorbikes and aerial platforms.

Ratings range from 80 A to 180 A, with 12, 24 and 36 V DC coils and different coil duties for each application. Contacts sit in a protective housing, the cover is fully protected from oil, water and dust, and the contactors are supplied with brackets already mounted.

The TECNO 6 series (T106, T206) includes 1NO and 1NO+1NC models with 6 mm coil terminals. The TECNO 4 series (T154, T204), designed for heavy duty with prolonged or high inrush currents, has screw coil connections. Silver-alloy double-break main contacts resist arcing; NC contacts are not suitable for making or breaking current.

Fast drop-out (8–10 ms) and relatively long pull-in (25–45 ms) allow safe motor reversal with two contactors. Suppressor diodes increase drop-out time, so a diode + resistor combination is recommended.

  • Heavy duty — DC5 utilisation category
  • Current — up to 180 A (50 %)
  • Protected contacts — housing closed against oil, water and dust
  • Mounting bracket — supplied fitted
  • Mechanical life — 2 million operations

Technical Specifications

Utilisation categoryDC5
Coil voltage12, 24, 36 V DC
Coil dutyT106, T206, T154, T204: 80 % intermittent · T106C, T206C: 50 % intermittent, max. 15 min · T106P: continuous
Ie (50 %) with 36 V coilT106: 75 A · T206: 100 A · T154 / T204: 90 A
Working voltage limits0.7–1.1 Vn (T106P: 0.85–1.1 Vn)
Terminal torque6 Nm
Operating temperature−25 °C to +40 °C
Mountingby bracket; horizontal or vertical with poles upwards
Norms2006/42/CE, 2014/35/UE, 2014/30/UE, EN 1175-1, EN 60947-4-1, EN 60529, EN 60204-1

The coil voltage suffix (X) is added to the part number: 12 V = 1, 24 V = 2, 36 V = 3

TypeMain contactsIe (50 %)Ie (100 %)Breaking capacity (15 ms)Coil powerPull-in / drop-outPart number
T1061NO120 A80 A480 A12 W30 / 10 msE T106AX
T106 P — continuous coil1NO120 A80 A480 A8 W30 / 10 msE T106PX
T106 C1NO + 1NC120 A80 A480 A22 W25 / 8 msE T106CX
T2061NO180 A150 A720 A20 W30 / 10 msE T206AX
T206 C1NO + 1NC180 A150 A720 A22 W25 / 8 msE T206CX
T1541NO150 A100 A600 A22 W45 / 10 msE T154AX
T2041NO180 A150 A720 A22 W45 / 10 msE T204AX

Catalogue (PDF) Instructions & Installation (PDF) Manufacturer Product Page