Small, powerful single-pole DC contactors and motor reversers: TL10, TL11, TLD18 and TL-AFS; 12–120 V DC coils, magnetic blowouts and latching version.

TL10 / TL11 Single-Pole Contactors and TLD18 COMBI

TL10 / TL11 Single-Pole Contactors and TLD18 COMBI

LOGO series DC contactors are very small yet very powerful, designed for direct-current traction and material handling: lift trucks, industrial cleaning machines, services on board ships and boats, and road and rail transport vehicles.

TL10 (1NO) and TL11 (1NO+1NC) are 100 A single-pole contactors. Coils have 6 mm terminals; standard duty is 50 % intermittent (max. 15 min), normalised voltage 12-24-36 V DC (contact us for 48 V). Reduced-consumption prolonged-duty (S) and continuous-duty (P) coils are available. For voltages above 36 V DC the open-cover version with permanent magnetic blowouts (M) is recommended; the polarities marked on the cover must be respected.

The TLD18 COMBI is a compact motor reverser made of two TL10 contactors with internal connections: TLD18A 2 × 1NO+1NC (4 poles), TLD18B 2 × 1NO (3 poles). It is supplied with 50 % intermittent coils at 12 and 24 V DC only and is not UL certified. Fast drop-out (10 ms) and relatively long pull-in (≈ 20 ms) allow safe reversals without the risk of contacts closing at the same time.

Silver-alloy double-break main contacts resist arcing and suit heavy duty; the cover is protected from oil, water and dust. NC contacts are not suitable for making or breaking current.

  • UL 583 — TL10 and TL11
  • Magnetic blowouts — option M, for above 36 V DC
  • Coil options — 50 % intermittent, prolonged (S), continuous (P)
  • Mounting bracket — E TL10ST-2
  • Mechanical life — 3 million operations

Technical Specifications

Utilisation categoryDC5
Coil voltage12, 24, 36 V DC (48 V on request)
Working voltage limits0.7–1.1 Vn (50 %) · 0.85–1.1 Vn (S, P)
Pull-in / drop-out time≤ 20 ms / ≤ 10 ms
Terminal torque4 Nm
Operating temperature−25 °C to +40 °C
Mountingscrews (max. 7 mm depth) or optional bracket; horizontal or vertical with poles upwards
Norms2006/42/CE, 2014/35/UE, 2014/30/UE, 2011/65/UE RoHS, EN 1175-1, EN 60947-4-1, EN 60204-1, UL 583

Types and ratings (Ie: 50 % intermittent, 300 op/h) — coil suffix added to the part number: 12 V = 1, 24 V = 2, 36 V = 3, 48 V = 4

TypeMain contactsIeIthBreaking capacity (UL 583)Coil powerPart number (with blowouts)
TL101NO100 A72 A400 A12 WE TL10 (E TL10M)
TL10 S — prolonged1NO100 A72 A400 A7 WE TL10S (E TL10MS)
TL10 P — continuous1NO100 A72 A400 A5 WE TL10P (E TL10MP)
TL111NO + 1NC100 A72 A450 A12 WE TL11 (E TL11M)
TL11 P — continuous1NO + 1NC100 A72 A450 A5 WE TL11P (E TL11MP)
TLD18A2 × 1NO + 1NC, 4 polesas TL10E TLD18A
TLD18B2 × 1NO, 3 polesas TL10E TLD18B

TL10 / TL11 / TLD18 Catalogue (PDF) Manufacturer Product Page

TL-AFS Contactors (100 / 150 / 250 A)

TL-AFS Contactors (100 / 150 / 250 A)

LOGO TL-AFS contactors come in 100, 150 and 250 A (continuous) current classes as single-pole (1NO or 1NO+1NC) contactors and motor reversers (2 × 1NO+1NC), used on lift trucks, industrial cleaning machines, electric vehicles, hydraulic pumps and winches and aerial platforms.

Coils have double 6.3 mm faston terminals and suit intermittent, prolonged or continuous duty. Silver-alloy double-break contacts suit heavy duty. Without magnets the contactors work up to 48 V DC; with magnetic blowouts up to 96 V DC on the 100 and 150 A models and up to 80 V DC on the 250 A models. The housing is supplied open for blowout or closed for better contact protection.

Options: auxiliary contacts, magnetic blowouts, mounting brackets, oversized contacts, knurled contacts for signal currents, suppressor diode and a latching version that reduces coil consumption.

  • Current — up to 475 A short-time (25 %)
  • Coils — 12 – 120 V DC
  • Magnetic blowouts — for higher voltages
  • Auxiliary contacts — on request
  • Latching version — low coil consumption

Technical Specifications

Coil voltages12, 24, 36, 48, 72, 80, 96, 120 V DC (up to 80 V on 250 A models)
Working voltage limits0.7–1.1 Vn (50 %) · 0.85–1.1 Vn (100 %)
Drop-out voltage0.15 Vn
Mechanical life1 × 10⁶ operations
Terminal torque6 Nm (M8) · 9 Nm (M10)
MountingM4 / M5 screws or omega bracket; horizontal or vertical with poles upwards
Operating temperature−25 °C to +40 °C
Norms2006/42/CE, 2006/95/CE, 2004/108/CE, 2011/65 RoHS, EN 1175-1, EN 60947-4-1, EN 60204-1

Types and current ratings (by intermittent duty)

TypeMain contacts25 %50 %100 %Max. voltage (without / with magnets)Coil power (50 %)Terminals
TL-AFS 191NO180 A150 A100 A48 / 96 V DC20 WM8
TL-AFS 151NO + 1NC180 A150 A100 A48 / 96 V DC20 WM8
TL-AFS 7112 × 1NO + 1NC180 A150 A100 A48 / 96 V DC20 WM8
TL-AFS 8191NO275 A225 A150 A48 / 96 V DC33 WM8
TL-AFS 8181NO + 1NC275 A225 A150 A48 / 96 V DC33 WM8
TL-AFS 7172 × 1NO + 1NC275 A225 A150 A48 / 96 V DC33 WM8
TL-AFS 8811NO475 A360 A250 A48 / 80 V DC34 WM10
TL-AFS 7991NO475 A360 A250 A48 / 80 V DC38 WM10
TL-AFS 7981NO + 1NC475 A360 A250 A48 / 80 V DC38 WM10
TL-AFS 7972 × 1NO + 1NC475 A360 A250 A48 / 80 V DC38 WM10