Small, powerful single-pole DC contactors and motor reversers: TL10, TL11, TLD18 and TL-AFS; 12–120 V DC coils, magnetic blowouts and latching version.

TL10 / TL11 Single-Pole Contactors and TLD18 COMBI
LOGO series DC contactors are very small yet very powerful, designed for direct-current traction and material handling: lift trucks, industrial cleaning machines, services on board ships and boats, and road and rail transport vehicles.
TL10 (1NO) and TL11 (1NO+1NC) are 100 A single-pole contactors. Coils have 6 mm terminals; standard duty is 50 % intermittent (max. 15 min), normalised voltage 12-24-36 V DC (contact us for 48 V). Reduced-consumption prolonged-duty (S) and continuous-duty (P) coils are available. For voltages above 36 V DC the open-cover version with permanent magnetic blowouts (M) is recommended; the polarities marked on the cover must be respected.
The TLD18 COMBI is a compact motor reverser made of two TL10 contactors with internal connections: TLD18A 2 × 1NO+1NC (4 poles), TLD18B 2 × 1NO (3 poles). It is supplied with 50 % intermittent coils at 12 and 24 V DC only and is not UL certified. Fast drop-out (10 ms) and relatively long pull-in (≈ 20 ms) allow safe reversals without the risk of contacts closing at the same time.
Silver-alloy double-break main contacts resist arcing and suit heavy duty; the cover is protected from oil, water and dust. NC contacts are not suitable for making or breaking current.
- UL 583 — TL10 and TL11
- Magnetic blowouts — option M, for above 36 V DC
- Coil options — 50 % intermittent, prolonged (S), continuous (P)
- Mounting bracket — E TL10ST-2
- Mechanical life — 3 million operations
Technical Specifications
| Utilisation category | DC5 |
|---|---|
| Coil voltage | 12, 24, 36 V DC (48 V on request) |
| Working voltage limits | 0.7–1.1 Vn (50 %) · 0.85–1.1 Vn (S, P) |
| Pull-in / drop-out time | ≤ 20 ms / ≤ 10 ms |
| Terminal torque | 4 Nm |
| Operating temperature | −25 °C to +40 °C |
| Mounting | screws (max. 7 mm depth) or optional bracket; horizontal or vertical with poles upwards |
| Norms | 2006/42/CE, 2014/35/UE, 2014/30/UE, 2011/65/UE RoHS, EN 1175-1, EN 60947-4-1, EN 60204-1, UL 583 |
Types and ratings (Ie: 50 % intermittent, 300 op/h) — coil suffix added to the part number: 12 V = 1, 24 V = 2, 36 V = 3, 48 V = 4
| Type | Main contacts | Ie | Ith | Breaking capacity (UL 583) | Coil power | Part number (with blowouts) |
|---|---|---|---|---|---|---|
| TL10 | 1NO | 100 A | 72 A | 400 A | 12 W | E TL10 (E TL10M) |
| TL10 S — prolonged | 1NO | 100 A | 72 A | 400 A | 7 W | E TL10S (E TL10MS) |
| TL10 P — continuous | 1NO | 100 A | 72 A | 400 A | 5 W | E TL10P (E TL10MP) |
| TL11 | 1NO + 1NC | 100 A | 72 A | 450 A | 12 W | E TL11 (E TL11M) |
| TL11 P — continuous | 1NO + 1NC | 100 A | 72 A | 450 A | 5 W | E TL11P (E TL11MP) |
| TLD18A | 2 × 1NO + 1NC, 4 poles | as TL10 | E TLD18A | |||
| TLD18B | 2 × 1NO, 3 poles | as TL10 | E TLD18B |

TL10 / TL11 / TLD18 Catalogue (PDF) Manufacturer Product Page

TL-AFS Contactors (100 / 150 / 250 A)
LOGO TL-AFS contactors come in 100, 150 and 250 A (continuous) current classes as single-pole (1NO or 1NO+1NC) contactors and motor reversers (2 × 1NO+1NC), used on lift trucks, industrial cleaning machines, electric vehicles, hydraulic pumps and winches and aerial platforms.
Coils have double 6.3 mm faston terminals and suit intermittent, prolonged or continuous duty. Silver-alloy double-break contacts suit heavy duty. Without magnets the contactors work up to 48 V DC; with magnetic blowouts up to 96 V DC on the 100 and 150 A models and up to 80 V DC on the 250 A models. The housing is supplied open for blowout or closed for better contact protection.
Options: auxiliary contacts, magnetic blowouts, mounting brackets, oversized contacts, knurled contacts for signal currents, suppressor diode and a latching version that reduces coil consumption.
- Current — up to 475 A short-time (25 %)
- Coils — 12 – 120 V DC
- Magnetic blowouts — for higher voltages
- Auxiliary contacts — on request
- Latching version — low coil consumption
Technical Specifications
| Coil voltages | 12, 24, 36, 48, 72, 80, 96, 120 V DC (up to 80 V on 250 A models) |
|---|---|
| Working voltage limits | 0.7–1.1 Vn (50 %) · 0.85–1.1 Vn (100 %) |
| Drop-out voltage | 0.15 Vn |
| Mechanical life | 1 × 10⁶ operations |
| Terminal torque | 6 Nm (M8) · 9 Nm (M10) |
| Mounting | M4 / M5 screws or omega bracket; horizontal or vertical with poles upwards |
| Operating temperature | −25 °C to +40 °C |
| Norms | 2006/42/CE, 2006/95/CE, 2004/108/CE, 2011/65 RoHS, EN 1175-1, EN 60947-4-1, EN 60204-1 |
Types and current ratings (by intermittent duty)
| Type | Main contacts | 25 % | 50 % | 100 % | Max. voltage (without / with magnets) | Coil power (50 %) | Terminals |
|---|---|---|---|---|---|---|---|
| TL-AFS 19 | 1NO | 180 A | 150 A | 100 A | 48 / 96 V DC | 20 W | M8 |
| TL-AFS 15 | 1NO + 1NC | 180 A | 150 A | 100 A | 48 / 96 V DC | 20 W | M8 |
| TL-AFS 711 | 2 × 1NO + 1NC | 180 A | 150 A | 100 A | 48 / 96 V DC | 20 W | M8 |
| TL-AFS 819 | 1NO | 275 A | 225 A | 150 A | 48 / 96 V DC | 33 W | M8 |
| TL-AFS 818 | 1NO + 1NC | 275 A | 225 A | 150 A | 48 / 96 V DC | 33 W | M8 |
| TL-AFS 717 | 2 × 1NO + 1NC | 275 A | 225 A | 150 A | 48 / 96 V DC | 33 W | M8 |
| TL-AFS 881 | 1NO | 475 A | 360 A | 250 A | 48 / 80 V DC | 34 W | M10 |
| TL-AFS 799 | 1NO | 475 A | 360 A | 250 A | 48 / 80 V DC | 38 W | M10 |
| TL-AFS 798 | 1NO + 1NC | 475 A | 360 A | 250 A | 48 / 80 V DC | 38 W | M10 |
| TL-AFS 797 | 2 × 1NO + 1NC | 475 A | 360 A | 250 A | 48 / 80 V DC | 38 W | M10 |