Optical linear encoder L35 is an incremental linear displacement measuring device that has up to 3.240 mm measuring length, up to ±3 µm accuracy grades to any meter within the ML depending on measuring length demanded.

L35 Incremental Linear Encoder
Optical linear encoder L35 is an incremental linear displacement measuring device that has up to 3.240 mm measuring length, up to ±3 µm accuracy grades to any meter within the ML depending on measuring length demanded. L35 series is more vibration resistant than the L18 series of encoders.
Mechanical data
| Measuring lengths (ML), mm | 70; 120; 170; 220; 270; 320; 370; 420; 470; 520; 620; 720; 820; 920; 1020; 1140; 1240; 1340; 1440; 1540; 1640; 1740; 1840; 1940; 2040; 2140; 2240; 2340; 2440; 2540; 2640; 2740; 2840; 2940; 3040; 3140; 3240 (other intermediate lengths on request) |
|---|---|
| Accuracy grades to any meter within the ML (at 20°C) | for ML 70 to 2040: ±5 μm; ±3 μm (optional) for ML 2040 to 3240: ±10 μm |
| Grating period | 20 μm; 40 μm (optional) |
| Reference marks (RI) | standard for ML ≤ 1020 mm: 35 mm from both ends of ML standard for ML ≥ 1140 mm: 45 mm from both ends of ML optional: one RI at any location, or two or more RI’s separated by distances of n x 50 mm or distance-coded |
| Max. traversing speed | when interpolation factor is 1,2,5,10: 1 m/s when interpolation factor is 25: 0.5 m/s when interpolation factor is 50: 0.4 m/s |
| Required moving force with sealing lips | < 5 N |
| Protection (IEC 529) | with compressed air: IP64 |
| Weight | 0.4 kg + 2.8 kg/m |
| Operating temperature | 0…+50°C |
| Storage temperature | -20…+70°C |
| Permissible vibration (40 to 2000 Hz) | ≤ 150 m/s² |
| Permissible shock (11 ms) | ≤ 300 m/s² |
Electrical data
| Version | L35-A ∫ µApp | L35-AV ∫ 1 Vpp | L35-F Π TTL; HTL (on request) |
|---|---|---|---|
| Supply voltage | + 5 V ± 5 % | + 5 V ± 5 % | + 5 V ± 5 %; + 12V ± 5 % |
| Max. supply current (without load) | 90 mA | 90mA | 120 mA / 130 mA |
| Light source | LED | LED | LED |
| Incremental signals | Two sinusoidal I1 and I2 Amplitude at 1 kΩ load: – I1 = 7 – 16 µA – I2 = 7 – 16 µA | Differential sine +A / -A and +B / -B Amplitude at 120 kΩ load: – A = 0.6 – 1.2 V – B = 0.6 – 1.2 V | Differential square-wave U1 / U1 and U2 / U2. Signal levels at 20 mA load current: – low (logic “0”) < 0.5 V at Up = ±5V – high (logic “1”) > 2.4 V at Up = ±5V – low (logic “0”) < 1.5 V at Up = ±12V (HTL) – high (logic “1”) > (Up – 2)V at Up = ±12V (HTL) |
| Reference signal | One quasi-triangular I0 peak per revolution. Signal magnitude at 1 kΩ load: – I0 = 2 – 8 µA (usable component) | One quasi-triangular +R and its complementary -R per revolution. Signal magnitude at 120 Ω load: – R = 0.2 – 0.8 V (usable component | One differential square-wave U0 / U0 per revolution. Signal levels at 20 mA load current: – low (logic “0”) < 0.5 V at Up = ±5V – high (logic “1”) > 2.4 V at Up = ±5V – low (logic “0”) < 1.5 V at Up = ±12V(HTL) – high (logic “1”) > (Up – 2)V at Up = ±12V (HTL) |
| Maximum operating frequency | 50 kHz | 50 kHz | 50 kHz, when interpolation factor is 1, 2, 5 ,10 1000 kHz, when interpolation factor is 25, 50 |
| Direction of signals | I2 lags I1 for clockwise rotation (viewed from shaft side) | + B lags + A in clockwise rotation (viewed from shaft side) | U2 lags with U1 in clockwise rotation (viewed from shaft side) |
| Standard cable length | 3 m; without connector | 3 m; without connector | 3 m; without connector |
| Maximum cable length | 5 m | 25 m | 25 m |
Order code
L35 – X1 – X2 – X3 – X4 – X5 – X6/X7 ORDER EXAMPLE: L35-F05-2040-O-10-C-CP03/C12
| Output Signals and Resolution (X1) | Measuring Length (X2) | Reference Mark (X3) | Accuracy (X4) | Cable or Connector Outlet (X5) | Cable Length (X6) | Connector Type (X7) |
|---|---|---|---|---|---|---|
| A – Sinusoidal AV – Sinusoidal F01 – TTL 0.1um F02 – TTL 0.2um F05 – TTL 0.5 um F10 – TTL 1.0um F25 – TTL 2.5 um F50 – TTL 5.0 um | 0070 – 70mm 0520 – 520mm … 1240 – 3240mm | N – none IR S – standard M – every 50 mm K – distance coded Ln/XXX – n`IR with 50-fold steps /XXX distance of the first IR from the beginning of ML, mm 0 – selection by magnets (standard – one magnet(IR) in ML middle) | 03 – ±3 um (optional)* 05 – ±5 um 10 – ±10um *depends on length | S – version S (cable outlet) C – version C (connector outlet) | 01 – 1m 02 – 2m 03 – 3m … CP01 – 1m armoured CP02 – 2m armoured CP03 – 3m armoured … | W – without connector B12 – round, 12 pins C9 – round, 9 pins C12 – round, 12 pins D9 – flat, 9 pins D15 – flat, 15 pins RS10 – round, 10 pins ONC – round, 10 pins |
Compatible accessories
- NK - External interpolator
- CS3000 - Digital readout unit
- CS5500 - Digital readout unit
- C9 - 9-pins round connector
- C12 - 12-pins round connector
- D9 - 9-pins flat connector
- D15 - 15-pins flat connector
- B12 - 12-pins round connector
- RS10 - 10-pins round connector
- ONC - 10-pins round connector

Precizika Encoder Catalogue (PDF) Datasheet (PDF) 2D Drawing (DWG) 3D Model (STEP)