Mechanical data

Measuring lengths (ML), mm70; 120; 170; 220; 270; 320; 370; 420; 470; 520; 620; 720; 820; 920; 1020; 1140; 1240
(other intermediate lengths on request)
Accuracy grades to any meter within the ML (at 20°C)±10; ±5; ±3 (optional)
Grating period20 μm; 40 μm (optional)
Reference marks (RI)standard for ML ≤ 1020 mm: 35 mm from both ends of ML
standard for ML ≥ 1140 mm: 45 mm from both ends of ML
optional: one RI at any location, or two or more RI’s separated by distances of n x 50 mm or distance-coded
Max. traversing speedwhen interpolation factor is 1,2,5,10: 1 m/s
when interpolation factor is 25: 0.5 m/s
when interpolation factor is 50: 0.4 m/s
Required moving force with sealing lips< 3 N
Protection (IEC 529)with compressed air: IP64
Weight0.4 kg + 0.8 kg/m
Operating temperature0…+50°C
Storage temperature-20…+70°C
Permissible vibration (40 to 2000 Hz)≤ 30 m/s²
Permissible shock (11 ms)≤ 100 m/s²

Electrical data

VersionL18T-A ∫ µAppL18T-AV ∫ 1 VppL18T-F Π TTL
Supply voltage+ 5 V ± 5 %+ 5 V ± 5 %+ 5 V ± 5 %
Max. supply current (without load)90 mA120 mA120 mA
Light sourceLEDLEDLED
Incremental signalsTwo sinusoidal I1 and I2
Amplitude at 1 kΩ load:
– I1 = 7 – 16 µA
– I2 = 7 – 16 µA
Differential sine +A / -A and +B / -B
Amplitude at 120 kΩ load:
– A = 0.6 – 1.2 V
– B = 0.6 – 1.2 V
Differential square-wave U1 / U1 and U2 / U2. Signal levels at 20 mA load current:
– low (logic “0”) ≤ 0.5 V at Up =± 5V
– high (logic “1”) ≥ 2.4 V at Up =±5V
Reference signalOne quasi-triangular I0 peak per revolution. Signal magnitude at 1 kΩ load:
– I0 = 2 – 8 µA (usable component)
One quasi-triangular +R and its complementary -R per revolution. Signal magnitude at 120 Ω load:
– R = 0.2 – 0.8 V (usable component
One differential square-wave U0 / U0 per revolution. Signal levels at 20 mA load current:
– low (logic “0”) < 0.5 V at Up =± 5V
– high (logic “1”) > 2.4 V at Up =±5V
Maximum operating frequency50 kHz50 kHz50 kHz, when interpolation factor is 1, 2, 5 ,10
1000 kHz, when interpolation factor is 25, 50
Direction of signalsI2 lags I1 for clockwise rotation (viewed from shaft side)+ B lags + A in clockwise rotation (viewed from shaft side)U2 lags with U1 in clockwise rotation (viewed from shaft side)
Maximum rise and fall time––< 0.5 us
Standard cable length3 m; without connector3 m; without connector3 m; without connector
Maximum cable length5 m25 m25 m

Order code

L18T – X1 – X2 – X3 – X4 -X5 – X6/X7

Output Signals and Resolution (X1)Measuring Length (X2)Reference Mark (X3)Accuracy (X4)Cable or Connector Outlet (X5)Cable Length (X6)Connector Type (X7)
A – Sinusoidal
AV – Sinusoidal
F01 – TTL 0.1um
F02 – TTL 0.2um
F05 – TTL 0.5 um
F10 – TTL 1.0um
F25 – TTL 2.5 um
F50 – TTL 5.0 um
0070 – 70mm
0520 – 520mm
…
1240 – 1240mm
N – none IR
S – standard
M – every 50 mm
K – distance coded
Ln/XXX – n`IR with 50-fold steps /XXX distance of the first IR from the beginning of ML, mm
03 – ±3 um
05 – ±5 um
10 – ±10um
S – version S (cable outlet)
C – version C (connector outlet)
01 – 1m
02 – 2m
03 – 3m
…
CP01 – 1m armoured
CP02 – 2m armoured
CP03 – 3m armoured
…
W – without connector
B12 – round, 12 pins
C9 – round, 9 pins
C12 – round, 12 pins
D9 – flat, 9 pins
D15 – flat, 15 pins
RS10 – round, 10 pins
ONC – round, 10 pins

Order examples: L18T-A-1240-K-05-C-03/C9